Hydrocarbon Dew Point and Moisture Analyzer for Natural Gas Features Moisture: Measurement range: 1ppm V to 1000ppm V . Measurement technology: Tuneable Diode Laser Spectroscopy. Latest generation of TDLAS – moisture measurements are independent to changes in background gas composition. Class-leading accuracy ±1ppm V even with widely varying gas compositions. Hydrocarbon Dew-Point: Fully automatic analysis. Fundamental chilled mirror principle. HCDP measurement range: up to ∆ 55K measurement depression from main unit operating temperature. HCDP measurement technology: direct photo-detection of hydrocarbon condensate. General: Low maintenance. Easy to install with a small footprint.

Authorised DistributorISO 17025 Calibration LabSingapore Stock

Specifications

Moisture Measurement Range1ppmV to 1000ppmV
Moisture Measurement TechnologyTuneable Diode Laser Spectroscopy
Moisture Accuracy±1ppmV
HCDP Measurement Rangeup to Δ 55K measurement depression from main unit operating temperature
HCDP TechnologyDirect photo-detection of hydrocarbon condensate
Compatible GasNatural gas containing up to 20% hydrogen

Description

Hydrocarbon dew point (HCDP) and moisture are key quality parameters to ensure the quality of pipeline transmission gas. With the combined Condumax II and OptiPEAK TDL600 analyzer system pipeline operators have the assurance of the most widely accepted automatic hydrocarbon dew point analyzer together with the latest development of spectroscopic moisture measurement techniques in a single, convenient analyzer system.

Both the OptiPEAK TDL600 and Condumax II are suitable for use with natural gas containing up to 20% hydrogen with no further modification required.

Visit the product pages for Condumax II and OptiPEAK TDL600 for full technical specifications.

Suitable for use with natural gas containing up to 20% hydrogen with no further modification required.

Need this instrument calibrated?

Unitest Instruments operates Singapore's SAC-SINGLAS accredited calibration laboratory (ISO/IEC 17025, Lab No. LA-2023-0845-C). We provide traceable calibration with full documentation for most test & measurement instruments.

Book Calibration →

Get a price for the Michell Condumax II and OptiPEAK TDL600 Dew-Point Analyzer

Send your enquiry — we reply with pricing, availability & lead time within 1 business day.

+65

Protected by reCAPTCHA — Google Privacy Policy and Terms apply.

Michell Condumax II and OptiPEAK TDL600 Dew-Point Analyzer | Unitest Instruments Singapore