7508/7511/7512 Refrigerated Temperature Calibration Baths

7508/7511/7512 Refrigerated Temperature Calibration Baths

Refrigerated baths with exceptional temperature stability and uniformity at low temperatures down to -10 °C Set-point resolution of 0.001 °C Fully automated with bath interface package and MET/TEMP II software CFC-free refrigerants Used by national labs for comparison calibrations and fixed-point cell maintenance.

Get a price for the 7508/7511/7512 Refrigerated Temperature Calibration Baths

Response within 1 business day · No obligation

+65

Protected by reCAPTCHA. Google Privacy Policy and Terms apply.

Prefer to buy online? Visit the Unitest online shop.

Authorised DistributorISO 17025 Calibration LabSingapore Stock

Specifications

Temperature SettingDigital display with push-button data entry
Range7508: –5 °C to 110 °C; 7511 & 7512: –10 °C to 110 °C
Stability7508: ±0.0007 °C at 25 °C (water), ±0.001 °C at 25 °C (mineral oil); 7511 & 7512: ±0.0008 °C at 0 °C (ethanol), ±0.0008 °C at 25 °C (water), ±0.003 °C at 100 °C (oil 5012)
Uniformity7508: ±0.003 °C at 25 °C (water), ±0.004 °C at 25 °C (mineral oil); 7511 & 7512: ±0.003 °C at 0 °C (ethanol), ±0.003 °C at 25 °C (water), ±0.005 °C at 100 °C (oil 5012) (working zone as defined in the user manual)
Set-Point Resolution0.001 °C
Display Resolution0.01 °C or 0.001 °C
Digital Setting Accuracy±1 °C
Digital Setting Repeatability±0.005 °C
Heaters500 and 1000 Watts
Access Opening (call for customs)7508: 324 x 184 mm (12.75 x 7.25 in); 7511: 127 x 254 mm (5 x 10 in); 7512: 162 x 292 mm (6.38 x 11.5 in)
Depth7508: 331 mm (13 in); 7511: 305 mm (12 in); 7512: 457 mm (18 in)
Wetted Parts304 Stainless Steel
Power115 VAC (±10 %), 60 Hz, 12 A (1380 VA); or 230 VAC (±10 %), 50 Hz, 6.39 A (1470 VA); or 208/230 VAC, 60 Hz, 6.39 A (1400 VA)
Volume7508: 42 liters (11.2 gal); 7511: 27 liters (7.2 gal); 7512: 42 liters (11.2 gal)
Weight7508: 61 kg (135 lb); 7511: 56.7 kg (125 lb); 7512: 68 kg (150 lb)
Size7508: 610 x 775 x 483 mm (24 x 30.5 x 19 in); 7511: 559 x 686 x 401 mm (22 x 27 x 15.8 in); 7512: 762 x 686 x 401 mm (30 x 27 x 15.8 in)
AutomationUse the 1586A Super-DAQ to automate temperature sensor calibration
CommunicationRS-232 + USB A/B
DisplayColor LCD module, TFT, 4.3 in diagonal, 480 x 272 pixels, LED backlight
RefrigerantR290 Propane (A3 flammable)

Description

The Fluke Calibration 7508, 7511 and 7512 refrigerated temperature calibration baths deliver exceptional temperature stability and uniformity at low temperatures down to -10 °C. They are used by national labs for comparison calibrations and fixed-point cell maintenance.

The range of available bath sizes lets you calibrate a wide variety of platinum resistance thermometers (PRTs), thermistors and thermocouples, as well as triple-point-of-water cells and blackbody cones.

Each bath is fully automated with a bath interface package and Fluke Calibration MET/TEMP II automation software, controlled from a PC over USB or RS-232 through a 1586A Super-DAQ. Direct-drive stirrer motors and full fluid drainage make maintenance easy, and the baths use CFC-free refrigerants.

Contact Unitest Instruments for model-specific specifications, pricing and availability.

Need this instrument calibrated?

Unitest Instruments operates Singapore's SAC-SINGLAS accredited calibration laboratory (ISO/IEC 17025, Lab No. LA-2023-0845-C). We provide traceable calibration with full documentation for most test & measurement instruments.

Book Calibration →

Get a price for the 7508/7511/7512 Refrigerated Temperature Calibration Baths

Send your enquiry. We reply with pricing, availability & lead time within 1 business day.

+65

Protected by reCAPTCHA. Google Privacy Policy and Terms apply.

Before you go

Need help finding the right instrument?

Tell us what you're after and we'll point you to the right model, fast.

We usually reply within a couple of hours · no spam, ever.