18 Boon Lay Way, #04-93, Tradehub 21, Singapore 609966
BL-1D - Humidity and Temperature Data Logger

SKU: BL-1D

BL-1D - Humidity and Temperature Data Logger

Features 3 types available: BL-1D: hPa, °Cdp, %RH, °C HL-1D: %RH, °C TL-1D: °C High measurement accuracy of ±3.0 %RH, ±0.3 °C, ±3 hPa Compact with high level of IP protection High storage capacity: 32,000 lines Programmable start and stop times via HW4 software Free evaluation and configuration software HW4-lite FDA 21 CFR Part 11 / GAMP 5-compliant HW4 software EN 12830 certified (V3.0 devices)

Get a price for the BL-1D - Humidity and Temperature Data Logger

Response within 1 business day · No obligation

+65

Protected by reCAPTCHA — Google Privacy Policy and Terms apply.

Authorised DistributorISO 17025 Calibration LabSingapore Stock

Specifications

Humidity Measurement MethodROTRONIC HygroMer IN-1
Humidity Accuracy (23°C ±5°C)±3.0 %RH
Humidity Resolution0.1 %RH
Humidity Measurement Range0...100 %RH (non-condensing)
Temperature Measurement MethodNTC
Temperature Accuracy (23°C ±5°C)±0.3 °C
Temperature Resolution0.1 °C
Temperature Measurement Range-30...70°C
Pressure Measurement MethodBosch BMP280
Pressure Accuracy (23°C ±5°C)±3 hPa
Pressure Resolution1 hPa
Pressure Measurement Range300...1100 hPa
Dew Point Measurement MethodCalculation (from %RH and °C)
Dew Point Calculation StandardWMO standard
Logging Interval30 s...24 h
Storage Capacity32,000 lines
FunctionMIN / MAX / AVG
DisplayLCD, 2 lines
Display Refresh Rate5 sec (standard); in logging mode same as logging interval
LED Indicators2 LEDs. Right LED flashes green when logging, left LED flashes red when limits reached or low battery
CommunicationUSB-Mini port
SoftwareHW4 V3.4.1 or later (BL-1D: V3.9 or later); HW4-lite (free evaluation/configuration)
Range of Application (Temperature)-30...70°C
Range of Application (Humidity)0...100 %RH (non-condensing)
Battery1 x CR2
Battery Life3 years (at 1 h logging interval, room temperature)
IP ProtectionIP67
Weight85 g
Dimensions90 x 60 x 23 mm
FDA/GMP CompatibilityFDA 21 CFR Part 11 / GAMP 5-compliant HW4 software
StandardsEN 12830 (from device version V3.0)
AccessoriesMini USB cable AC0003 (contained in xL-1D-SET)
Available VariantsBL-1D (hPa, °Cdp, %RH, °C); HL-1D (%RH, °C); TL-1D (°C)

Description

Barometric pressure, humidity temperature and dew point data logger. Compact, dependable and inexpensive.

Need this instrument calibrated?

Unitest Instruments operates Singapore's SAC-SINGLAS accredited calibration laboratory (ISO/IEC 17025, Lab No. LA-2023-0845-C). We provide traceable calibration with full documentation for most test & measurement instruments.

Book Calibration →

Get a price for the BL-1D - Humidity and Temperature Data Logger

Send your enquiry — we reply with pricing, availability & lead time within 1 business day.

+65

Protected by reCAPTCHA — Google Privacy Policy and Terms apply.

Related Products

View all in this category
Before you go

Need help finding the right instrument?

Tell us what you're after and we'll point you to the right model, fast.

We usually reply within a couple of hours · no spam, ever.

BL-1D - Humidity and Temperature Data Logger | Unitest Instruments Singapore