18 Boon Lay Way, #04-93, Tradehub 21, Singapore 609966
Fluke 106 Palm-sized Digital Multimeter

SKU: Fluke 106

Fluke 106 Palm-sized Digital Multimeter

Key features Voltage, resistance, continuity, capacitance Input terminal for ac and dc current measurements to 10 A and current Data hold

Authorised DistributorISO 17025 Calibration LabSingapore Stock

Specifications

AC Volts Range (40 Hz to 500 Hz)6.000 V / 60.00 V / 600.0 V
AC Volts Resolution0.001 V / 0.01 V / 0.1 V
AC Volts Accuracy1.0% + 3
DC Volts Range6.000 V / 60.00 V / 600.0 V
DC Volts Resolution0.001 V / 0.01 V / 0.1 V
DC Volts Accuracy0.5% + 3
AC Millivolts Range600.0 mV
AC Millivolts Resolution0.1 mV
AC Millivolts Accuracy3.0% + 3
Resistance Range400.0 Ω / 4.000 kΩ / 40.00 kΩ / 400.0 kΩ / 4.000 MΩ / 40.00 MΩ
Resistance Resolution0.1 Ω / 0.001 kΩ / 0.01 kΩ / 0.1 kΩ / 0.001 MΩ / 0.01 MΩ
Resistance Accuracy0.5% + 3 / 0.5% + 2 / 0.5% + 2 / 0.5% + 2 / 0.5% + 2 / 1.5% + 3
Capacitance Range50.00 nF / 500.0 nF / 5.000 μF / 50.00 μF / 500.0 μF / 1000 μF
Capacitance Resolution0.01 nF / 0.1 nF / 0.001 μF / 0.01 μF / 0.1 μF / 1 μF
Capacitance Accuracy2% + 5 / 2% + 5 / 5% + 5 / 5% + 5 / 5% + 5 / 5% + 5
Frequency Range (10 Hz to 100 kHz)50.00 Hz / 500.0 Hz / 5.000 kHz / 50.00 kHz / 100.0 kHz
Frequency Resolution0.01 Hz / 0.1 Hz / 0.001 kHz / 0.01 kHz / 0.1 kHz
Duty Cycle Range1% to 99%
Duty Cycle Resolution0.1%
AC Current Range (40 Hz to 200 Hz)4.000 A / 10.00 A
AC Current Resolution0.001 A / 0.01 A
AC Current Accuracy1.5% + 3
DC Current Range4.000 A / 10.00 A
DC Current Resolution0.001 A / 0.01 A
DC Current Accuracy1.5% + 3
AC Volts Overload Protection600 V
AC Volts Input Impedance (Nominal)>10 MΩ <100 pF
AC Volts Common Mode Rejection Ratio>60 dB at dc, 50 Hz or 60 Hz
AC Millivolts Overload Protection600 mV
AC Millivolts Input Impedance (Nominal)>1 MΩ, <100 pF
AC Millivolts Common Mode Rejection Ratio>80 dB at 50 Hz or 60 Hz
DC Volts Overload Protection600 V
DC Volts Input Impedance (Nominal)>10 MΩ <100 pF
DC Volts Common Mode Rejection Ratio>100 dB at dc, 50 Hz or 60 Hz
DC Volts Normal Mode Rejection Ratio>60 dB at 50 Hz or 60 Hz
Maximum Voltage Between any Terminal and Earth Ground600 V
Display (LCD)6000 counts, updates 3/sec
Battery Type2 AAA, NEDA 24A, IEC LR03
Battery Life200 hours minimum
Operating Temperature0 °C to 40 °C
Storage Temperature-30 °C to 60 °C
Operating HumidityNon-condensing when <10°C; ≤90% at 10°C to 30°C; ≤75% at 30°C to 40°C
Operating Humidity (40 MΩ Range)≤80% at 10°C to 30°C; ≤70% at 30°C to 40°C
Operating Altitude2000 m
Storage Altitude12,000 m
Temperature Coefficient0.1 × (specified accuracy) /°C (<18°C or >28°C)
Fuse Protection for Current Inputs11A, 1000V Fast Fuse, Fluke specified part only
Size (HxWxL)142 mm x 69 mm x 28 mm
Weight200 g
IP RatingIEC 60529: IP 40
SafetyIEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic EnvironmentIEC 61326-1: Portable

Description

Product overview: Fluke 106 Palm-sized Digital Multimeter
The Fluke 106 digital multimeter is made to fit the way you work! It is designed to fit in the palm of your hand and go with you no matter where your job takes you.

Get a price for the Fluke 106 Palm-sized Digital Multimeter

Send your enquiry — we reply with pricing, availability & lead time within 1 business day.

+65

Protected by reCAPTCHA — Google Privacy Policy and Terms apply.