Key features CAT III 600 V safety rating Current and voltage measurements Measures resistance and continuity to check for broken wires Data hold and backlit display to keep you working safe and fast
Specifications
| AC Voltage Range (40 Hz to 500 Hz) | 6.000 V / 60.00 V / 600.0 V |
| AC Voltage Resolution | 0.001 V / 0.01 V / 0.1 V |
| AC Voltage Accuracy | ±1.0% + 3 |
| DC Voltage Range | 6.000 V / 60.00 V / 600.0 V |
| DC Voltage Resolution | 0.001 V / 0.01 V / 0.1 V |
| DC Voltage Accuracy | ±0.5% + 3 |
| Exchange Millivolts Range | 600.0 mV |
| Exchange Millivolts Resolution | 0.1 mV |
| Exchange Millivolts Accuracy | ±3.0% + 3 |
| Diode Test Range | 2.000 V |
| Diode Test Resolution | 0.001 V |
| Diode Test Accuracy | ±10% |
| Resistance Range | 400.0 Ω / 4.000 kΩ / 40.00 kΩ / 400.0 kΩ / 4.000 MΩ / 40.00 MΩ |
| Resistance Resolution | 0.1 Ω / 0.001 kΩ / 0.01 kΩ / 0.1 kΩ / 0.001 MΩ / 0.01 MΩ |
| Resistance Accuracy | ±0.5%+3 / ±0.5%+2 / ±0.5%+2 / ±0.5%+2 / ±0.5%+2 / ±1.5%+3 |
| Capacitance Range | 50.00 nF / 500.0 nF / 5.000 µF / 50.00 µF / 500.0 µF / 1000 µF |
| Capacitance Resolution | 0.01 nF / 0.1 nF / 0.001 µF / 0.01 µF / 0.1 µF / 1 µF |
| Capacitance Accuracy | ±2%+5 / ±2%+5 / ±5%+5 / ±5%+5 / ±5%+5 / ±5%+5 |
| Frequency Range (10 Hz – 100 kHz) | 50.00 Hz / 500.0 Hz / 5.000 kHz / 50.00 kHz / 100.0 kHz |
| Frequency Resolution | 0.01 Hz / 0.1 Hz / 0.001 kHz / 0.01 kHz / 0.1 kHz |
| Frequency Accuracy | ±0.1% + 3 |
| Duty Cycle Range | 1% to 99% |
| Duty Cycle Resolution | 0.10% |
| Duty Cycle Accuracy | ±1% typical |
| AC Current Range (40 Hz – 200 Hz) | 4.000 A / 10.00 A |
| AC Current Resolution | 0.001 A / 0.01 A |
| AC Current Accuracy | ±1.5% + 3 |
| DC Current Range | 4.000 A / 10.00 A |
| DC Current Resolution | 0.001 A / 0.01 A |
| DC Current Accuracy | ±1.5% + 3 |
| AC Voltage Overload Protection | 600 V |
| AC Voltage Input Impedance | >10 MΩ <100 pF |
| AC Voltage Common Mode Rejection Ratio | >60 dB at 50 Hz or 60 Hz at DC current |
| Exchange Millivolts Overload Protection | 600 mV |
| Exchange Millivolts Input Impedance | >1 MΩ, <100 pF |
| Exchange Millivolts Common Mode Rejection Ratio | >80 dB at 50 Hz or 60 Hz |
| DC Voltage Overload Protection | 600 V |
| DC Voltage Input Impedance | >10 MΩ <100 pF |
| DC Voltage Common Mode Rejection Ratio | >100 dB at 50 Hz or 60 Hz at DC current |
| DC Voltage Normal Mode Rejection Ratio | >60 dB at 50 Hz or 60 Hz |
| Maximum Voltage to Ground | 600 V |
| Display | 6000 counts, updated three times per second |
| Battery Type | Two AAA batteries (NEDA 24A, IEC LR03) |
| Battery Life | At least 200 hours |
| Operating Temperature | 0 °C to 40 °C |
| Storage Temperature | -30 °C to 60 °C |
| Working Humidity | No condensation below 10 °C; ≤90% at 10 °C to 30 °C; ≤75% at 30 °C to 40 °C |
| Working Humidity (40 MΩ range) | ≤80% at 10 °C to 30 °C; ≤70% at 30 °C to 40 °C |
| Working Elevation | 2000 m |
| Storage Altitude | 12,000 m |
| Temperature Coefficient | 0.1 × (specified accuracy) / °C (<18 °C or >28 °C) |
| Current Input Fuse Protection | 11A, 1000V fast-melting type, must use Fluke designated parts |
| Dimensions (H × W × D) | 142 mm × 69 mm × 28 mm |
| Weight | 200 g |
| Protection Level | IEC 60529: IP 40 |
| Safety | IEC 61010-1: 600 V CAT III, pollution degree 2 |
| Electromagnetic Environment | IEC 61326-1: Portable |
| Drop Test | 1-meter drop test |
Datasheet
Download datasheet (PDF)Description
Product overview: Fluke 107 Palm-sized, CAT III Digital Multimeter
The Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 offers a comfortable grip, weighs only 200 g, and is easy to carry.
Fluke 107 measurement test functions
- AC and DC voltage
- AC and DC current
- Resistance
- Capacitance
- Diode
- Frequency and duty-cycle
Fluke 107 comes ready to work
The Fluke 107 comes with a TL75 Hard Point™ Test Lead Set. It’s one pair (red, black) of 48 inch (1.22 meter) test leads with right-angle, shrouded banana plugs. The meter also includes a SmartStrap™ intelligent magnetic multi-purpose lanyard that lets you hang the Fluke 107 from any ferrous surface or support the meter at an angle for easy viewing.