


SKU: Condumax II
Hydrocarbon Dew-Point Analyzer - Michell Condumax II
On-Line Dew-Point Analysis in Natural Gas Features Fully automatic on-line analysis Objective, highly repeatable measurements 0.5 °C hydrocarbon dew-point accuracy Fundamental chilled mirror principle Patented detection technique Self-cleaning No purge or cooling gas required Optional water dew-point analysis Modbus RTU IECEx, ATEX, UKCA, cQPSus and GOST Ex certifications
Specifications
| Hydrocarbon Dew-Point Accuracy | 0.5 °C |
| Analysis Type | Fully automatic on-line |
| Detection Method | Fundamental chilled mirror principle (patented "Dark Spot" technique) |
| Water Dew-Point | Optional analysis available (Michell Ceramic Metal-Oxide Moisture Sensor) |
| Communication Protocol | Modbus RTU |
| Safety Certifications | IECEx, ATEX, UKCA, cQPSus, GOST Ex |
| Maximum Operating Pressure | 138 barg |
| Hydrogen Compatibility | Suitable for natural gas with up to 20% hydrogen (no modification required) |
| Purge/Cooling Gas | Not required |
| Self-Cleaning | Yes |
| Enclosure | Compact explosion-proof |
| Sampling Systems | Indoor and outdoor available as standard |
Datasheet
Download datasheet (PDF)Description
The Condumax II hydrocarbon and water dew-point analyzer provides continuous, automatic measurements of these two critical parameters of natural gas quality. It uses the ‘Dark Spot’ direct chilled-mirror technique to measure hydrocarbon dew point with high accuracy and long-term reliability. Water dew point measurements are provided by Michell’s Ceramic Metal-Oxide Moisture Sensor.
The Condumax II is housed in a compact explosion-proof enclosure. Both indoor and outdoor sampling systems are available as standard providing comprehensive sample conditioning natural gas at up to 138 barg. For specific applications and requirements, we offer a custom engineering design service.
Condumax II is suitable for use with natural gas containing up to 20 % hydrogen with no further modification required.
| Suitable for use with natural gas containing up to 20 % hydrogen with no further modification required. |
Need this instrument calibrated?
Unitest Instruments operates Singapore's SAC-SINGLAS accredited calibration laboratory (ISO/IEC 17025, Lab No. LA-2023-0845-C). We provide traceable calibration with full documentation for most test & measurement instruments.
Get a price for the Hydrocarbon Dew-Point Analyzer - Michell Condumax II
Send your enquiry — we reply with pricing, availability & lead time within 1 business day.

