18 Boon Lay Way, #04-93, Tradehub 21, Singapore 609966
Temperature & Humidity Monitoring · Singapore

Warehouse Temperature and Humidity Monitoring and Data Loggers in Singapore

A warehouse temperature and humidity data logger is an instrument that records the temperature and relative humidity inside a storage area at set time intervals, so you have a continuous, time-stamped record you can hand to an auditor and an alarm the moment conditions drift out of range. In a Singapore warehouse this matters more than in most climates: ambient conditions here sit around 25 to 31°C and 80 to 90% relative humidity all year, and every time a loading door opens that warm, wet outside air pushes straight into the space. That is the load your logger has to see, and it is the reason a device chosen for a temperate-climate warehouse is often the wrong device here.

This page covers the two ways Singapore warehouses solve this: standalone data loggers you place, download and file, and wireless or networked monitoring systems that report continuously to a gateway or the cloud with live alerts. Both are below, with real models, real specifications and honest guidance on which fits which type of warehouse. Unitest Instruments is an authorised Fluke and Rotronic distributor in Singapore and has supplied test and measurement equipment here for over 20 years.

Get a warehouse monitoring quote

Response within 1 business day · No obligation

+65

Protected by reCAPTCHA — Google Privacy Policy and Terms apply.

View the loggers

Standalone logger or a wireless monitoring system: which do you need?

Most warehouse buyers are really choosing between two things. A standalone logger is a self-contained unit with its own battery and memory that you place on a rack, leave to record, then collect and download over USB. It is simple, needs no infrastructure, and is ideal where you need proof of conditions rather than a live feed. A wireless monitoring system puts fixed loggers around the warehouse that transmit continuously to a gateway and to server or cloud software, so you get live dashboards, automatic alarms by SMS or email, and audit records generated for you. It costs more and needs network setup, but for a regulated cold room or a pharmaceutical store it is usually what the standard expects.

The third case is the quick check. A handheld temperature and humidity meter is for spot audits, commissioning and troubleshooting a specific spot, not for the continuous record.

If your warehouse is…What most Singapore sites chooseWhy
Ambient, general storage (no regulatory temperature limit, you just want a record and drift alerts)Standalone logger (HygroLog HL-1D or HL-20D-SET1)Low cost, no infrastructure, place and download. Enough for internal quality and insurance evidence.
Chilled or cold room (food, chilled distribution)Standalone logger rated to the low temperature (BL-1D) or a small wireless system for live alarmsBelow-zero and near-zero conditions need a logger rated for the range. Live alarms matter when a chiller failure means spoiled stock overnight.
FreezerLogger rated to the freezer range plus alarmingConfirm the logger’s operating range covers your lowest set point, and we will match the model at quote stage.
Pharmaceutical / medical device store (HSA GDP, GDPMDS)Wireless monitoring system (Rotronic RMS) with FDA 21 CFR Part 11-compliant recordsGDP-type audits expect continuous monitoring, alarmed excursions, secure records and mapping. The RMS platform is built for this.
Cold chain / multi-zone facilityWireless RMS across zones, with a mapping study to place the fixed points correctlyOne system, many measurement points, one audit record. Mapping decides where the fixed loggers go.

A warehouse temperature mapping study is a service, delivered by our calibration side, not a product. If you need the study, see warehouse temperature mapping (section below).

Real models · real specifications

The loggers and monitoring systems we supply

Every model, specification and link below is real and verified against our product catalogue. Not sure which fits? Tell us the space and we will recommend one.

Standalone loggers

HygroLog HL-1D
Rotronic

HygroLog HL-1D

The compact warehouse workhorse. A low-cost, compact standalone logger for humidity and temperature. The one most general warehouses start with.

  • Accuracy: ±3.0% RH and ±0.3°C
  • Memory: 32,000 readings
  • Battery life: up to 3 years
  • HW4 / HW4-lite software, FDA 21 CFR Part 11-compliant; conforms to EN 12830
  • High IP-rated compact housing with a clear LCD and visual alerts
View product
HygroLog HL-20D-SET1
Rotronic

HygroLog HL-20D-SET1

Ready-to-deploy warehouse set. Ships complete (logger, battery, cable) so it works straight out of the box. Rotronic list warehouses, factory halls, museums, clean rooms and shipping as its intended applications.

  • Range of application: -10 to 60°C, 0 to 100% RH
  • Memory: 20,000 data points
  • Logging interval: freely selectable, 5 s to 1 h
  • Battery operation; integrated clock time-stamps every reading; programmable alarms
View product
BL-1D
Rotronic

BL-1D

Rugged multi-parameter logger (adds pressure and dew point). A sealed, dependable logger recording barometric pressure, humidity, temperature and dew point. The IP67 rating suits harsher warehouse and cold-room corners.

  • Accuracy: ±3.0% RH, ±0.3°C, ±3 hPa
  • Range: -30 to 70°C, 0 to 100% RH (non-condensing)
  • Memory: 32,000 lines; logging interval 30 s to 24 h
  • IP67; battery life up to 3 years (at 1 h interval)
  • HW4 software FDA 21 CFR Part 11-compliant; EN 12830 certified (V3.0 devices)
  • Also available as HL-1D (%RH, °C) and TL-1D (°C only) variants
View product
HygroLog HL-NT3-D
Rotronic

HygroLog HL-NT3-D

High-end, multi-probe logger. For sites that need several measurement points from one logger, or door-contact monitoring. Takes any HygroClip 2 probe and can monitor up to 7 probes plus two external contacts (such as a door contact).

  • Two external probe inputs plus optional internal probe; up to 7 probes
  • Storage: 47,000 records per MB (32 MB card included)
  • Range of application: -30 to 70°C, 0 to 100% RH
  • Logging interval: 5 s to 24 h; integrated clock for time-stamping
  • Networkable to PC via docking station (USB, Ethernet, WLAN); audible alarm; IP40
  • Validated HW4 software complies with FDA 21 CFR Part 11 (electronic records and signatures)
View product
Amprobe TR300
Amprobe

Amprobe TR300

Indoor air-quality and general monitoring logger. A simple, wall-mountable logger with a large display and built-in alarms. A budget option for offices, packing halls and general indoor air-quality monitoring.

  • RH range 0 to 100%, accuracy ±3% (10 to 90% RH)
  • Memory: up to 16,000 readings (selectable)
  • USB interface with Amprobe Download Suite software
  • Audible and visible LED alarms; wall-mount, self-standing or tripod
View product

Wireless / networked monitoring system

The Rotronic Monitoring System (RMS) is for regulated stores and multi-zone facilities that need live monitoring, automatic alarms and secure records rather than manual downloads. Fixed loggers transmit to a gateway and to RMS server or cloud software, and keep recording even if power or the network drops. Fixed monitoring uses interchangeable HygroClip 2 probes: Rotronic's HC2 probes offer better than 1% RH per year long-term stability and are 100% field-interchangeable, so a probe swap does not mean recalibrating the whole system.

RMS Wall Data Logger (LOG-L)
Rotronic

RMS Wall Data Logger (LOG-L)

Fixed wall-mounted logger for the RMS platform. Transmits continuously and keeps recording even if power or the network drops.

  • Stores 44,000 pairs of measured values; fail-safe internal battery, 3-year life
  • LAN interface; works with RMS Gateway, RMS Server Software and RMS Cloud
  • Conforms to FDA 21 CFR Part 11 / GAMP 5
View product
RMS DIN Rail Data Logger
Rotronic

RMS DIN Rail Data Logger

Panel-mounted RMS logger for integrating monitoring into control cabinets and plant.

  • Input (RMS-DI) and output (RMS-DO) variants; RMS-DI stores 75,000 values
  • Fail-safe internal battery, 3-year life; wireless or LAN interface
  • Works with RMS Gateway, RMS Server Software and RMS Cloud
View product

Handheld (spot checks and commissioning)

Fluke 971 Temperature Humidity Meter
Fluke

Fluke 971 Temperature Humidity Meter

A pocket meter for walking the warehouse, checking a suspect zone, or commissioning before you place fixed loggers. Measures humidity, temperature, dew point and wet bulb, stores 99 records. Not a continuous-record device.

View product

See the full Rotronic humidity range.

What your records actually have to show

Meeting Singapore compliance

Most Singapore warehouses do not buy a logger because they want data. They buy it because an auditor, a customer or a standard asks them to prove the goods were stored in-range. What “in-range” and “proof” mean depends on which regime you fall under.

Health and pharmaceutical products (HSA Good Distribution Practice)

Companies storing and distributing therapeutic products under HSA's GDP guidance are expected to keep storage areas within a defined temperature range, monitor them continuously with calibrated devices, alarm and investigate excursions, and carry out a temperature mapping study to prove the whole space stays in range, not just the spot where the sensor sits. Records must be retained and available for audit.

Medical devices (GDPMDS / SS 620)

Importers and wholesalers of medical devices in Singapore work to GDPMDS, which similarly expects controlled, monitored and recorded storage conditions where the product requires it.

Food (SFA)

Chilled and frozen food storage must hold safe temperatures and keep records that show it. Cold-room temperature records are a standard part of an SFA-licensed operation.

Food safety systems (HACCP)

Where temperature is a critical control point, HACCP requires it to be monitored, recorded and acted on when it goes out of limit. A logger with alarms and a clean export is what closes that loop.

Across all of these, three things decide whether a logger is fit for the job: how often it records (the logging interval, which every logger above lets you set), how long the record is kept and how securely (why FDA 21 CFR Part 11-compliant software matters for regulated sites), and whether the measurement is traceable (that the logger itself reads true). That last point is calibration.

On calibration, stated honestly. The loggers on this page can be supplied with calibration from our SAC-SINGLAS accredited laboratory (accreditation LA-2023-0845-C), which gives you a certificate traceable to national standards, the kind of evidence an auditor accepts. A temperature mapping study of your warehouse is a separate engagement and is not itself an accredited service; what is accredited is the calibration of the loggers used to carry it out. If you need the study rather than the equipment, we run that through our calibration team's warehouse temperature mapping service.

Not sure which logger? Tell us the space.

There is no single right answer, and picking the wrong range or interval is the usual mistake. Tell us the type of storage, the temperature range you need to hold, and the standard you are being audited against, and we will recommend the model and the logging setup, and quote it. We respond to enquiries within 2 business hours. Need loggers for a short-term project only? We also offer equipment rental.

Warehouse monitoring FAQs

Straight answers on choosing and using temperature and humidity loggers for a Singapore warehouse.

What temperature and humidity range should a logger cover for a Singapore warehouse?

For a general ambient warehouse in Singapore, the logger needs to comfortably cover roughly 20 to 40°C and up to 90 to 100% RH, because indoor conditions track the local climate of about 25 to 31°C and 80 to 90% RH and spike higher near loading doors. For chilled or freezer storage, the logger must be rated down to your lowest set point. Check the operating range on the datasheet against your actual conditions before buying.

What is the difference between a data logger and a monitoring system?

A standalone data logger records to its own memory and you download it over USB when you need the data. A monitoring system uses fixed loggers that transmit continuously to a gateway and to server or cloud software, giving you live readings, automatic alarms and audit records generated for you. Loggers suit general storage and evidence; monitoring systems suit regulated cold rooms and pharmaceutical stores that need live alarms and secure records.

How often should the logger record?

The logging interval depends on how fast conditions can change and what your standard expects. Warehouses commonly log every 5 to 15 minutes; a fast-changing cold room may log more frequently. Every logger on this page lets you set the interval, from a few seconds up to 24 hours on some models.

Do I need calibrated loggers for an audit?

Yes, if the record is used as compliance evidence. An auditor wants to know the logger reads true, which means a calibration certificate traceable to national standards. Unitest can supply the loggers with calibration from our SAC-SINGLAS accredited laboratory. A calibrated logger with a certificate is what makes your temperature record defensible.

Can you carry out a temperature mapping study of my warehouse?

Yes, through our calibration team. Mapping places loggers across the space to prove the whole warehouse, not just one spot, stays in range, which HSA GDP and similar standards expect. The mapping study is a service; what is accredited is the calibration of the loggers used in it, not the study itself.

Do these systems meet HSA GDP or FDA 21 CFR Part 11 requirements?

The Rotronic loggers and RMS monitoring system run on HW4 or RMS software that is FDA 21 CFR Part 11 / GAMP 5-compliant for electronic records and signatures, which is what GDP-type audits look for. The equipment supports compliance; your own procedures, mapping and record-keeping complete it. Tell us the standard you are audited against and we will confirm the right configuration.

Can I rent loggers instead of buying?

Yes, for short-term needs such as a one-off mapping exercise, a commissioning project or a seasonal peak, loggers can be rented. See our rental page or ask us for a short-term monitoring quote.

Get a warehouse monitoring quote

Tell us your warehouse type, temperature range and the standard you report against. We will recommend the right loggers or monitoring system and quote within 1 business day.

  • Authorised Fluke & Rotronic distributor · 20+ years in Singapore
  • SAC-SINGLAS accredited calibration · LA-2023-0845-C
  • Enquiries answered within 2 business hours

Get a warehouse monitoring quote

Storage type, temperature range and the standard you report against. We reply within 1 business day.

+65

Protected by reCAPTCHA — Google Privacy Policy and Terms apply.

Before you go

Need help finding the right instrument?

Tell us what you're after and we'll point you to the right model, fast.

We usually reply within a couple of hours · no spam, ever.